Traulsen RBC200 Refrigerator User Manual


 
READY TO DEFROST
REQUIRED IN XX MIN.
REMOVE FOOD
CANCEL START
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
VII. OPERATING THE BLAST CHILL CONTROL - HOLD MODE & DEFROST
-16-
VII. e - REFRIGERATED HOLD MODE:
At the completion of a chill cycle, regardless of the mode used, the Traulsen
blast chiller reverts to normal refrigerated holding mode of 37°F. Hold mode
can also be manually selected at any time (i.e. interrupting the chill cycle) by
using the HOLD MODE feature. When in the holding mode both the mainteance
and blast chill compressors will operate during cooling portions of the cycle.
The main menu should be displayed on the control. To initiate a HOLD MODE
follow the below instructions:
STEP ONE: From the MAIN MENU, select MORE by pressing the button to
the right of where this is shown on the display. The menu
shown will then change to display additional menu options.
STEP TWO: Press the button to the left of where HOLD PROD (hold product)
is shown on the display.
HOLDING will show on the display. The timer will indicate run
time in the lower left corner of the display: Hr: Min: Sec:
(hours:minutes:seconds).
VII. f - DEFROST:
When not in a chill cycle, the Traulsen blast chiller will automatically start a
defrost cycle every three hours while in refrigerated HOLD mode. However, a
defrost can also be manually initiated by following the below procedure.
STEP ONE: From the MAIN MENU, select MORE by pressing the button to
the right of where this is shown on the display. The menu
shown will then change to display additional menu options.
STEP TWO: Press the button to the left of where DEFROST is shown on the
display. The menu will then change slightly to show REMOVE
FOOD, CANCEL and START.
NOTE: Remove food from the blast chiller before proceeding.
STEP THREE: Press the button to the right of where START is shown on the
display to initiate a manual defrost cycle. The defrost cycle will
run for 40 minutes or until both the maintenance and blast chill
coil temperatures reach 50°F. Once initiated, the defrost cycle
will only terminate on time or temperature, and cannot be
manually terminated.
For model RBC100, a common evaporator coil is used for the
both the blast chill and maintenance compressors.
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
Main Menu Display
HOLDING AIR: 34°F
1 37
°F 37°F 3
2 37
°F
0:00:04 EXIT
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
NOTE: HOLD mode does not retain temperature vs. time data in memory; as
a result printed reports are not available.
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
Main Menu Display
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
DEFROSTING
MAINT 50
°F
BLAST 49
°F
00:10:05
XX = Number of minutes until next scheduled defrost.