III. f - CORD & PLUG:
All Traulsen Blast Chill models (except model RBC100
which is supplied with a cord set but no plug) are supplied
with a cord & plug attached (for models RBC200 and
RBC200RT, the cord and plug supplied is for the self-con-
tained maintenance compressor only, the 4HP remote con-
densing unit requires a separate electrical connection of
its own). It is shipped coiled at the top of the cabinet, se-
cured by a nylon strip. For your safety and protection, all
units supplied with a cord and plug include a special three-
prong grounding plug on the service cord. Select only a
certified electrical outlet with grounding plug for power
source. NOTE: Do not under any circumstances, cut or
remove the round grounding prong from the plug, or use
an extension cord.
III. g - ELECTRICAL REQUIREMENTS:
Model RBC50 is normally provided with two (2) grounding
type cords with plugs (NEMA 5-15P). Two (2) separate 115/
60/1 volt, 20 amp, grounded circuits with receptacle must
be provided by a certified electrician to assure proper op-
eration of the equipment
(see figure 43).
Model RBC100 is normally provided with a grounding type
cord without a plug. A dedicated 220/60/1 volt, 4 wire, 20
amp grounded circuit with receptacle should be provided
by a certified electrician to assure that the computerized
control is not adversely affected by the operation of other
equipment.
Models RBC200/RBC200RT are normally provided with one
(RBC400/RBC400RT are provided with two) grounded
cordset (NEMA 5-20P). A dedicated 115/60/1 volt, 20 amp,
grounded circuit should be provided by a certified
electrician to assure that the computerized control is not
adversely affected by the operation of other equipment.
III. h - PROPER CLEARANCES:
Model RBC50: Make certain that there are no obstructions
in front of the louver panels on the left and right front sides
of the unit. This will allow for sufficient air flow to the re-
frigeration system and maintenance access.
Model RBC100: A minimum of 4 clearance on the right
side, 6 on the left side and 6 clearance in the rear (see
figure 5). This will allow for sufficient air flow to the
refrigeration system and maintenance access.
Models RBC200/RBC200RT & RBC400/RBC400RT: Insure
an overhead clearance of 12 and a rear clearance of 4(see
figure 6). This will allow for sufficient air flow to the
refrigeration system and maintenance access.
6 Clearance
In Rear
4 Clearance
In Rear
III. INSTALLATION (continued)
-6-
Fig. 5
Fig. 6
4 Clearance On Right
Side For Drain Tube
Air
Intake
12 Clearance
On Top
Fig. 4
115/60/1
Outlet #1
115/60/1
Outlet #2
6 Clearance
On Left
4
Clearance
On Right