VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR
VII. i - ACCESSING SYS PAR SETTING LEVEL:
SYS PAR represents the supervisor level of access to the SmartChill
®
controller,
allowing on-site adjustment to the factory preset operating parameters.
To enter the SYSPAR access level please follow the below procedure.
STEP ONE: From the MAIN MENU, select MORE by pressing the button to
the right of where this is shown on the display. The menu
shown will then change to display additional menu options.
STEP TWO: Press the button to the right of where SETUP is shown on the
display. Note when you first enter SETUP, only Preset Supervisor
is available (as delivered, only the factory preset supervisor’s
PIN access or ID is set-up).
Press the buttons to the left and right of where PASSWORD is
shown on the display to scroll to the factory preset PIN of
57. Press the button to the right of where ENTER appears on
the control to enter this PIN number. The SETUP display menu
is displayed.
NOTE: If users have already been setup, select the supervisors name
using the UP or DOWN keys. On the next line, use the UP or
DOWN keys to enter their Password (or Personal Identification
Number). Press the button to the right of where ENTER appears
on the control to enter this selection. The SETUP display menu
is displayed.
STEP THREE: From the SETUP display menu , select the button to the right of
where SYS PAR is shown on the display. Refer to the diagram
on page 21 in order to access the various Sys Par settings
SELECT SUPERVISOR:
PRESET SUPERVISOR
PASSWORD (PIN): 57
CANCEL ENTER
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
SYS PAR: SET CLOCK
ITEM: MONTH
VALUE:APRIL
CANCEL ENTER
SYS PAR Menu Display