VII. OPERATING THE BLAST CHILL CONTROL - PRINTING
VII. g - PRINTING BATCH/CHILL CYCLE DATA:
Once a chill cycle is complete, data can be printed.
-17-
Press to select DATA.
Press to change to a previous date. Press to change to a future date.
For multi-batching, press to select probe. Press to select LABEL or BOTH.
Press to return to MAIN MENU. Press to print selection.
However, the following information can always be printed.
Press to select LIST.
Press to change to a previous date. Press to change to a future date.
Press to return to MAIN MENU. Press to print selection.
PRINT: CYCLE
4/03 08:40
PRB#1 RECORD
MAIN MENU PRINT
MAIN MENU 08:06:01
HOLD PROD PRINT
DEFROST SETUP
BACK
MAIN MENU AIR 35°F
BY TEMP BY PROD
BY TIME
08:05:01 MORE
PRINT: DATA
4/03 08:00
12 HOUR LOG
MAIN MENU PRINT
Optional Label Printer SampleStandard On-Board Printer Sample
REMOVED: 04/11/03 13:08
CYCLE TIME: 358 MINUTES
HIGHEST: 140
°
F LOWEST -7
°
F
TIME TO 70
°
F: 45 MINUTES
TIME TO 40
°
F: 75 MINUTES
STARTED: 04/11/03 13:08
0 40 70 140
112
106
96
89
84
79
75
70
66
63
60
57
54
51
49
49
47
46
44
42
40
38
13:09
13:10
13:11
13:12
13:13
13:14
13:15
13:16
13:17
13:18
13:19
13:20
13:21
13:22
13:23
13:24
13:25
13:26
13:27
13:28
13:29
13:30
CHILL CYCLE REPORT
MODE: FREEZE
FOOD PRODUCT:SOUP VEGETABLE
USER: BOB SMITH
PROBE #2
STARTED: 04/11/03 13:08
REMOVED: 04/11/03 13:08
CYCLE TIME: 358 MINUTES
HIGHEST: 140
°
F LOWEST -7
°
F
TIME TO 70
°
F: 45 MINUTES
TIME TO 40
°
F: 75 MINUTES
CHILL CYCLE REPORT
MODE: FREEZE
FOOD PRODUCT:SOUP VEGETABLE
USER: BOB SMITH
PROBE #2
NOTE:
When printing at the end of a BY TEMP cycle, the controller will print
an abbreviated Chill Cycle Report. Only the data from when the cycle
started until the desired target temperature was reached will be
printed. If for any reason after reaching the set temperature the
temperature increased above 40F during the HOLD cycle, that
information will be printed at the bottom of the Chill Cycle Report,