INSTALLATION (continued)
8
ELECTRICAL INSTALLATION
1. Fryer electrical diagram and troubleshooting schematic are
located on the inside of the fryer door.
2. The fryer is equipped with a three-prong grounding plug
(NEMA 15-5P) for your protection against shock hazard. The fryer
must be plugged directly into a properly grounded three-prong
receptacle (NEMA 15-5R).
3. The installation of this fryer must conform to local codes. In the
absence of local codes, the installation of this fryer must conform
with the National Electrical Code (ANSI Z223.1).
In Canada, CSA C22.2 is applicable.
4. Because the fryer draws less than 8 amps, two fryers may be
plugged into the same 15 amp circuit if required.
CAUTION:
ELECTRIC SHOCK
HAZARD
The grounding prong of the
electrical power cord is part of
a system designed to protect
you from injury in the event of
an electrical short.
DO NOT CUT OR REMOVE
THE GROUNDING PRONG
FROM THE PLUG.
Ungrounded electrical
equipment cause personal
injury and property damage.
371 301098 OpManual for WFGA-60FS Gas Fryer