WARNING:
FIRE HAZARD / HOT OIL
The HI-LIMIT THERMOSTAT is a FIRE PROTECTION DEVICE.
If tripping persists, clean debris from the space between the
hi-limit bulb and the element to enhance oil flow and facilitate reset.
Otherwise, contact your authorized Wells Service Agent for repairs.
DO NOT ATTEMPT TO BYPASS OR HOLD IN THE BUTTON OF
THE HI-LIMIT THERMOSTAT. A SERIOUS FIRE MAY RESULT.
WARNING
371 301098 OpManual for WFGA-60FS Gas Fryer
FEATURES & OPERATING CONTROLS
2
Fig. 1 WFGA-60FS Features & Operating Controls
1
POWER SWITCH
(FRYER-OFF-FILTER)
FRYER position energizes the FRYER and POWER LIGHT;
de-energizes FILTER PUMP. HEATING ELEMENTS energized
and regulate to setting on CONTROL THERMOSTAT (8).
OFF position de-energized FRYER and FILTER PUMP.
FILTER position de-energizes FRYER; energizes FILTER PUMP
SWITCH (6).
2 TIME KEY
Used to check and set menu times
3 TEMP KEY
Used to check and set cooking temperature
4 DIGITAL READOUT
LED display of various data and functions
5 UP ARROW KEY
Used to raise FRY BASKET and to increase program settings
6 DOWN ARROW KEY
Used to lower FRY BASKET and to decrease program settings
7 MENU KEYS
Used to start a menu time/temp cook cycle
Keys 1 thru 6 are programmable for time and temperature
Key 7 is available for individually set time/temp cook cycles
8 FUNCTION KEYS
Used to perform the functions of:
PAUSE
CLEAN
STANDBY
BASKET (raise/lower when used with up arrow & down arrow)
FILTER (acknowledgement warning signal)
FRONT VIEW
9
BACK VIEW
LOWER CONTROL PANEL
RESET
HI-LIMIT
UPPER CONTROL PANEL
8
10
3
4
5
WELLS
2
6
7
1234
56
7
TIME TEMP
HEAT READY MANUAL
MANUAL
PAUSE CLEAN STANDBY BASKET FILTER
FRYER
OFF
FILTER
1
11
12
13
18
19
14
20
21
15
16
17
22
23