Wells WFGA-60FS Fryer User Manual


 
PREPARATION PRIOR TO OPERATION
9
Press POWER SWITCH OFF.
Close DRAIN VALVE (lever horizontal).
Fill FRYPOT with 4 gallons of cold water.
Press POWER SWITCH to FRYER.
Wait 10 seconds, then press and hold CLEAN button for six seconds.
A beep will sound and readout will display “BOIL”.
Slowly add and stir in the LOW FOAMING COMMERCIAL FRYER
CLEANSER. Using the HIGH TEMPERATURE BRUSH supplied with
the fryer, stir until the cleanser is completely dissolved.
Time displayed is elapsed time. When display reads “1:30”, press
POWER SWITCH OFF. Allow the solution to cool to 120ºF or less.
Place a suitable METAL container under the DRAIN VALVE. Open
DRAIN VALVE (lever vertical) to drain the cleaning solution.
NOTE: Drain no more than 4” at a time into the container to prevent
splashing and spilling.
Dispose of used solution as required by local
ordinances.
Rinse frypot with clean water. Dry with a soft clean cloth.
IMPORTANT:
Use a LOW-FOAMING
COMMERCIAL fryer cleanser
only.
WARNING
WARNING:
BURN HAZARD
USE THE CLEAN BUTTON ONLY
USE ONLY LOW-FOAMING COMMERCIAL FRYER CLEANSER.
CAREFULLY FOLLOW CLEANSER
CLEANING INSTRUCTIONS AND WARNINGS
DO NOT LEAVE FRYER UNATTENDED WHILE BOILING OUT FRYPOT.
BE PREPARED TO TURN POWER SWITCH OFF SHOULD WATER BEGIN FOAMING
Boiling water can splatter and may cause serious injury
CLEAN
PRE-CLEANING PROCEDURE
371 301098 OpManual for WFGA-60FS Gas Fryer