OPERATION - OPTIONAL FILTER WAND (continued)
18
371 301098 OpManual for WFGA-60FS Gas Fryer
FILTERING OIL - NORMAL OPERATION
1. Prepare the filter reservoir pan for filtering.
2. Turn the DRAIN VALVE HANDLE down to
open the drain and fill the filter reservoir.
3. Be sure the 3-WAY VALVE HANDLE is in the left-right position
to direct the pump output to the frypot.
4. Press the FRYER-OFF-FILTER switch to the FILTER position.
5. Filter as per instructions described in Fryer Operation Manual.
NOTE:
If the FRYER-OFF-FILTER switch is pressed to the FILTER
position with the 3-way valve handle in the front-to-back position
(wand not installed), the filter pump will stall and then trip on the
internal safety. To reset:
1. Turn the 3-way valve to the left-right
position.
2. Press the FRYER-OFF-FILTER
switch to the OFF position.
3. Wait approximately 3 minutes for
the motor to cool.
4. Press the red reset button on the
front end of the filter motor until it
“clicks” and locks in.
5. Resume operation.
DANGER:
BURN HAZARD
Contact with hot oil will cause
severe burns.
Always wear protective clothing
and heat resistant gloves when
filtering the oil.
WARNING:
ELECTRIC SHOCK
HAZARD
All servicing requiring access to
non-insulated components must
be performed by qualified service
personnel. DO NOT open any
access panel that requires the
use of tools. Failure to heed this
warning may result in severe
electric shock.
IMPORTANT:
Be sure the 3-way valve in the
left-right position before pressing
the FRYER-OFF-FILTER switch
to the FILTER position.