24 Freedom SW Owner’s Guide
Operating the Freedom SW with the SCP
Reading the System Status Screen
The System Status screen displays:
Battery-related information (see Line 2)
Battery level and inverter/charger operating state (see Line 3)
Load information (see Line 4)
AC Input information (see Line 5)
System Status
menu EnInv EnChg Shr
Battery
BatLev
Load
AC In
12.1V -257A 84F
Invert
120V 10A 12A
0V 0A 0A
Menu arrow indicates the Enter
button. Pressing Enter displays
the Select Device menu.
Line 1
Line 2
Line 3
Line 4
Line 5
Field 1 Field 2 Field 3
Field 4
Field 5
Field 6 Field 8
Field 9 Field 10
Field 7
Field 11
Table 2
System Status Screen
Line 1 Label: “System Settings
Line 2 Label: Battery
Field 1: Total battery current. Negative value if the battery is discharging and
positive value when charging.
Field 2: Battery voltage
Field 3: Battery temperature
a
. Also, displays the highest temperature between
stacked inverters that are installed.
a. The unit of temperature can be changed in the SCP Config menu screen.
Line 3 Label: BatLev
Field 4: Displays a bar graph showing the approximate battery level.
Field 5: Freedom SW inverter/charger operating state
Line 4 Label: Load
Field 6: Inverter output voltage at load terminals of the inverter/charger. Voltage
is reported by the Master unit if more than one inverter/charger is installed.
Field 7: Master current
b
Field 8: Sum of all load current from both inverter and charger. Also, it displays
Slave (or L2 Master) current
d
.
b. When in a stacked inverter configuration.
Line 5 Label: AC In
Field 9: AC input voltage at AC In terminals of the inverter/charger. Voltage is
reported by the Master unit if more than one inverter/charger is installed.
Field 10: Master current
b
Field 11: Sum of all L1 AC input current
c
from both inverter and charger. Sum of
all load current from both inverter and charger. Also, it displays Slave (or L2
Master) current
d
.
c. Only L1 AC input is taken into account. L2 AC input current is not included in the sum in Freedom SW
inverter/charger models where there is L2 AC input.
d. In a single unit setup, the Slave (or L2 Master) will display 0A all the time mainly because of the absence
of a second unit. If two units are stacked, the Master and Slave (or L2 Master) current will display the appro-
priate current values.