TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
Keep away from combustibles.
WARNING Exercise extreme caution when servicing electrical equipment.
Unplug the dispenser when servicing, except when electrical tests are specified.
Follow recommended service procedures
Replace all protective shields or safety notices
PROBLEM
PROBABLE CAUSE
REMEDY
CDS and Powder Auto-Fill do not
run - Main power indicator on CDS
drawer front OFF
Product level in CDS is lower than
level Probe - CDS running; Powder
Auto-Fill door lamp is OFF
Product level in CDS is lower than
level Probe - CDS running; Powder
Auto-Fill door lamp flashes ON and
OFF
1. CDS power cord disconnected or
main power switch in 0 position.
1. The CDS DAY/NIGHT switch in the
NIGHT position.
2. The CDS DAY/NIGHT timer in the
NIGHT position.
3. Powder Auto-Fill power cord dis-
connected.
4. Powder Auto-Fill main power
switch in OFF position.
5. Powder Auto-Fill door is open.
1. Low product in Powder Auto-Fill.
Check that the power cord is con-
nected to proper electrical source
and that the CDS main power switch
is in the 1 position.
1. The CDS DAY/NIGHT switch
should be in the DAY position.
2. Reprogram the CDS DAY/NIGHT
timer.
3. Check that the Powder Auto-Fill is
plugged into the back of the CDS
auger motor cover.
4. Select the ON position of the main
power switch.
5. The Powder Auto-Fill door should
be closed securely.
Remove hopper and fill with pow-
dered mix.
29793 061599