Carrier 62E Ventilation Hood User Manual


 
19
Table 4 — Supply and Exhaust Fans Electrical Data (cont)
LEGEND
Table 5 — Electric Heat Electrical Data
LEGEND
FAN
OPTION
62E
CHASSIS
UNIT
V-Ph
FAN MOTOR
V-Ph W FLA Qty
M
K,L,M,
N,P,R
230-3 230-3 2900 7.29 2
400-3 460-3 2900 3.64 2
460-3 460-3 2900 3.64 2
575-3 460-3 2900 2.92 2
N
R,S,
T, U
230-3 230-3 2900 7.29 3
400-3 460-3 2900 3.64 3
460-3 460-3 2900 3.64 3
575-3 460-3 2900 2.92 3
P T,U
230-3 230-3 2700 6.79 7
400-3 460-3 2700 3.39 7
460-3 460-3 2700 3.39 7
575-3 460-3 2700 2.71 7
R T,U
230-3 230-3 2700 6.79 8
400-3 460-3 2700 3.39 8
460-3 460-3 2700 3.39 8
575-3 460-3 2700 2.71 8
FLA Full Load Amps
Qty Quantity
W—Watts
HEATER
UNIT AND HEATER
V-Ph
62E CHASSIS
kW FLA
2
17.39 115-1 B,7
8.70 230-1 B,C,2,7
5.03 230-3 B,C,D,E,2,3,4,7
2.51 400-3 B,C,D,E,2,3,4,7
2.51 460-3 B,C,D,E,2,3,4,7
2.01 575-3 B,C,D,E,2,3,4,7
5
43.48 115-1 B,7
21.74 230-1 B,C,2,7
12.57 230-3 B,C,D,E,H,2,3,4,5,7
6.28 400-3 B,C,D,E,H,2,3,4,5,7
6.28 460-3 B,C,D,E,H,2,3,4,5,7
5.03 575-3 B,C,D,E,H,2,3,4,5,7
8
20.11 230-3 D,E,H,3,4,5
10.05 400-3 D,E,H,3,4,5
10.05 460-3 D,E,H,3,4,5
8.04 575-3 D,E,H,3,4,5
10
25.13 230-3 E,H,K,L,4,5,6
12.57 400-3 E,H,K,L,4,5,6
12.57 460-3 E,H,K,L,4,5,6
10.05 575-3 E,H,K,L,4,5,6
15
37.70 230-3 H,K,L,M,N,5,6
18.85 400-3 H,K,L,M,N,5,6
18.85 460-3 H,K,L,M,N,5,6
15.08 575-3 H,K,L,M,N,5,6
20
50.26 230-3 H,K,L,M,N,P,5,6
25.13 400-3 H,K,L,M,N,P,5,6
25.13 460-3 H,K,L,M,N,P,5,6
20.11 575-3 H,K,L,M,N,P,5,6
FLA Full Load Amps
W—Watts