Cleveland Range OVEN STEAMER Oven User Manual


 
Maintenance and Cleaning
76
COMBI ATMOSPHERIC STEAM GENERATOR DESCALING PROCEDURE
(For DISSOLVE
®
Descaler Solution Part No. 106174)
This procedure will take approximately 3 hours to complete.
1. Turn ON the Combi at the Control Power Service
Disconnect switch located below the hand
shower. See Figure 6-2.
2. Turn ON the COMBI with the ON / OFF key
.
3. Open the door to the cooking compartment.
4. Run a manual steam generator rinse cycle.
To Empty and Rinse the Steam Generator:
a. Press the Smart Key
.
b. Select “Manual steam generator rinse”
with the Selector Dial
6019002_00
D
.
c. Confirm “Yes” with the Smart Key
.
d. Steam generator will rinse and begin to
refill to operating level.
4. Remove the cap from the descale port located at
the top of the unit (See Figure 6-1).
NOTE: DO NOT HEAT THE COMBI DURING
DESCALING.
5. While the unit is filling with water, use a funnel
(NOT INCLUDED) to add 3/4 gallon of
DISSOLVE
®
descaler solution into the
descaling port of 20.20 COMBIs, and 1/2 gallon
for all other models
While adding liquid to the unit through the
descaler inlets, pour slowly to avoid
overflow.
Wipe up any spills at once to avoid etching.
6. After the automatic fill cycle has ended, turn OFF
the Combi with the ON / OFF key
, and at the
Control Power Service Disconnect switch located
below the hand shower. See Figure 6-2.
WARNING
This procedure is slightly different depending on the model
being descaled. This entire procedure should be read and fully
understand as it applies to the model being descaled, before
be
g
innin
g
the actual descalin
g
o
p
eration.
Figure 6-1 Descaling Port
Located at Right Rear of the
Combi