Dacor DR30D-C Range User Manual


 
8
Planning the Installation
Self-Rimming Installation With
Raised Vent
• Only model DR30DI may be installed with a raised vent. Use
only Dacor raised vent model ERV3015.
• A self-rimming countertop configuration is required for raised
vent installation. On installations with a raised vent, when
sliding the range into position, it will stop when the rear of the
control panel or side panels contact the notches toward the
front of the countertop.
• The self-rimming installation of the DR30DI range and
ERV3015 raised vent create a “built-in” look where the range
trim overlaps the countertop on both sides and the raised
vent overlaps the countertop in back. It is also possible, if the
cabinets are deep enough, to self rim the front of the range
into the cabinet face immediately behind the control panel
and door trim or behind the side panels (see side views on
this and the facing page). The rear range trim will partially
cover the front of the raised vent chassis in back.
Model DR30DI
Range and
ERV3015
Raised Vent
With
H J K
Countertop self-
rimmed only
20 5/8”
(52.4 cm)
0” (0 cm) to
3 1/4”
(8.3 cm)
0” (0 cm) to
5 3/8” (13.7 cm)
Countertop and
Cabinet Front
Self-Rimmed
,
20 5/8” *
(52.4 cm)
NA
0” (0 cm) to
5 3/8” (13.7 cm)
Countertop and
Cabinet Front
Self-Rimmed (side
panels removed)
23 7/8” *
(60.6 cm)
NA
0” (0 cm) to
2 1/8” (5.4 cm)
* Cabinet face below countertop must be flush with back of notch
in countertop.
Countertop height for all self-rimming installations:
35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum
IMPORTANT: If the 3 1/4 inch side panels are removed, the
cabinet face must be flush with the back of the control panel.
rear wall recommended
Non-combustible
countertop opening
cabinet opening
below countertop
29 1/4” (74 3 cm)
27 1/2” (69.9 cm)
30” (76.2 cm)
2 9/16”
(6.5 cm)
10” min.
(25.4 cm)
both sides
Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)
Notch countertop
overhang to width of
cabinets
3/8” min. (1.0 cm)
countertop
overhang
raised vent opening
H
Combustible side
wall above range
below countertop
To cabinet face
To countertop
front
J
K
Model DR30DI/ERV3015 Countertop Self-Rimmed Only,
3 1/4 Inch Side Panels Not Removed
Top View
Side View
Cabinet face
Countertop
Range trim resting
on countertop
Back of
control
panel
DR30DI[H] range
3/8” min. (1.0 cm)
flat countertop
overhang required
behind cutout
28 11/16” (72.9 cm)
3 1/4 inch
side panel
ERV3015
raised vent
3/8” min. (1.0 cm) space
required behind ERV3015
chassis to clear stiffener
H
Cutout tolerances: +1/16” (+1.6 mm), -0