Dacor DR30D-C Range User Manual


 
14
Installation Instructions
Electrical Connection
WARNING
• Wire the range only in compliance with local ordinances.
• Before proceeding, turn off power to the electrical supply
at the circuit breaker panel for fuse box. Do not turn on
power to the range until instructed to do so in the Verifying
Proper Operation section of these instructions.
• Improper connection of the electrical wiring can cause an
electric shock hazard and damage the appliance. Dacor
is not responsible for damages resulting from improper
installation.
• The ground terminal (or lead) on the appliance must be
connected to a grounded, metallic, permanent wiring system
or grounding conductor.
• Do not use an extension cord with this appliance. Such use
may result in fire, electric shock or other personal injury.
• Do not install a fuse in the neutral or ground circuit. A fuse
in the neutral or ground circuit may result in an electric
shock hazard.
IMPORTANT:
• Some models come pre-wired at the factory with a 4-wire
appliance cord for connection to a 14-50R electrical
receptacle as specified on page 3. If the range being
installed is pre-wired, skip to Gas Connection on page 18.
This section does not apply to pre-wired units.
• Do not disconnect any of the wires inside the range electrical
box unless instructed to do so.
• Make sure that the
conduit or appliance
cord is long enough
to allow the range
to be pulled out
for service without
disconnecting it from
power.
Types of Electrical Connections
Refer to the product data label (see inside cover) for power
requirements.
There are four possible ways to wire the range:
• 4-wire appliance cord, where local codes permit
• 3-wire appliance cord, where local codes permit
• 4-wire conduit (see page 16)
• 3-wire conduit, where local codes permit (see page 16)
The sections on the following pages give directions for connecting
each type of wiring harness.
Put slack in
electrical wiring
and gas line
Appliance Cord Connections - Where Local
Code Permits
WARNING
Do not connect the green appliance wire to the neutral (white)
supply wire unless local building codes permit.
1. Remove the range electrical access cover from the back of
the range.
2. IMPORTANT: If using a 4-wire connection, loosen the
grounding screw and remove the neutral to ground jumper
link from the terminal block. Leave the link in place for 3-wire
connections.
3. Remove the conduit bracket from the bottom of the range
electrical box.
4. Disassemble and remove the strain relief from the appliance
cord (not included). Insert the tabs on the two parts of
the strain relief into the hole on the bottom of the box and
reassemble it so that the tabs are below the box and the
strain relief itself is inside the box.
Remove link on
4-wire installations
Remove conduit bracket
before strain relief installation
Terminal block
Strain relief
Reassemble with tabs
below and clamp above
Bottom of range
electrical box