Dacor DR30D-C Range User Manual


 
6
Planning the Installation
Cabinet Layout
WARNING
All maximum and minimum cabinet and countertop dimensions
and clearances stated in these instructions must be maintained
for safe operation.
• Carefully check the location where the range is to be
installed. For best performance, the range should be placed
away from drafts that may be caused by doors, windows and
heating and air conditioning outlets.
• To reduce the risk of personal injury and to reduce
accumulated smoke in the room, Dacor strongly recommends
installing a range hood or raised vent (model DR30DI[H]
only). A range hood should project horizontally a minimum of
five (5) inches beyond the face of the cabinets.
• Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
• Carefully note the requirements stated below for clearances
to walls and cabinets.
Gas and Electrical Service
• The shaded area shown below denotes the location of the
gas inlet and the electrical junction box/receptacle. This
is the recommended location. For replacement purposes,
the location of the existing utilities may be utilized provided
they do not interfere with the sides or rear of the range.
Check local building codes for permissible utility connection
locations.
• An external manual shut-off valve must be installed between
the gas inlet and the range for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
• Access to the gas shut-off valve when the unit is installed.
• Access to the remote circuit breaker panel or fuse box when
the range is in place.
• The gas supply piping, gas shut-off valve and the electrical
junction box or receptacle must be located so they do not
interfere with the range when it is installed.
• The junction box and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
Note 3
Note 6
E
F
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of
cabinet front, see Product Dimensions.
4
Consult local code for exact location requirements.
6
Model DR30D[H]: 37 7/8 (96.2 cm) max.
Model DR30DI[H]: 37 7/16 (95.1 cm) max.
2
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate); if installing an overhead
range hood, also check the hood specifications for minimum
required clearances.
1
Minimum distance to a combustible rear wall for model
DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H]
may be installed flush to rear wall, but non-combusible surface
or 9-inch backguard (PN ADB3009) is recommended.
Back wall
1
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
2
13” (33.0 cm)
max.
5
18” (45.7 cm)
min.
2, 5
Suggested
location of
utilities
4
5
This specification does not apply for cabinets located
greater than a horizontal distance of 10” (25.4 cm)
from the edge of the range.
Cutout tolerances: +1/16” (+1.6 mm), -0
E F***
36” (91.4 cm)*
30” (76.2 cm)**
30 1/16” (76.4 cm)
* Recommended ** Minimum
*** See following pages for self-rimming
installations
Required Cabinet Dimensions
Note 3
Note 6
E
F
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of
cabinet front, see Product Dimensions.
4
Consult local code for exact location requirements.
6
Model DR30D[H]: 37 7/8 (96.2 cm) max.
Model DR30DI[H]: 37 7/16 (95.1 cm) max.
2
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate); if installing an overhead
range hood, also check the hood specifications for minimum
required clearances.
1
Minimum distance to a combustible rear wall for model
DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H]
may be installed flush to rear wall, but non-combusible surface
or 9-inch backguard (PN ADB3009) is recommended.
Back wall
1
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
2
13” (33.0 cm)
max.
5
18” (45.7 cm)
min.
2, 5
Suggested
location of
utilities
4
5
This specification does not apply for cabinets located
greater than a horizontal distance of 10” (25.4 cm)
from the edge of the range.