Dacor DR30D-C Range User Manual


 
17
Installation Instructions
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Connecting the Conduit to the House
Electrical Junction Box
WARNING
• Do not ground the appliance to a gas supply pipe or hot
water pipe.
• Do not turn on power to the appliance without it being
permanently grounded.
• A grounded cold water pipe must have metal continuity to
electrical ground and must not be interrupted by insulating
materials. Any insulating materials must be jumpered with a
length of No. 4 copper wire securely clamped to bare metal
at both ends.
NOTE: The power supply must be properly polarized. Reverse
polarity will result in continuous sparking of the electrodes, even
after flame ignition. If there is any doubt as to whether the power
supply is properly polarized or grounded, have it checked by a
licensed electrician.
1. With the range positioned directly in front of the cabinet
cutout, feed the appliance wires into the junction box.
Depending upon local codes, utilize one of the three (3)
methods shown to connect the appliance to the junction box.
2. Connect the white wire from the appliance to the neutral
(white) supply wire in the junction box.
3. Connect the black wire from the appliance to the black (L1)
power supply wire in the junction box.
4. Connect the red wire from the appliance to the red (L2) power
supply wire in the junction box.
5. If using a 4-wire connection, connect the green wire to a
grounded supply wire in the junction box or to a grounded
cold water pipe. If connecting to a grounded cold water pipe:
◊ Use a separate copper grounding wire (No. 10 minimum)
to connect to the cold water pipe by means of a clamp
and an external grounding connector screw.
◊ If there are any materials that isolate the cold water pipe
from ground, jumper it with a No. 4 copper wire, clamped
on both ends.
6. Replace the junction box cover.
Fasten clamp
tightly on pipe
3-Wire Conduit-Junction Box
Connection with External Ground
Separate No. 10 (minimum)
copper grounding wire
Meter or other
insulating device
Bare metal
Metal
water pipe
Clamps
Insulated Pipe Jumper
No. 4
copper wire
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Connection to
power supply
Connection to
power supply
Connection to
power supply
Wire nut
4 places
Junction box
4-Wire Conduit-Junction
Box Connection
Connection to
appliance
Connection to
appliance
Connection to
appliance
Wire nut
3 places
Junction box
Junction box
3-Wire Conduit-Junction
Box Connection