Dacor DR30D-C Range User Manual


 
16
Installation Instructions
L1 terminal
L1 terminal
L2 terminal
L2 terminal
Black wire
Red wire
White wire
Green wire
Red wire
White wire
Black wire
Conduit strain
relief nut
Conduit strain
relief nut
Neutral terminal
Neutral terminal
Neutral to ground
jumper link
Neutral to ground
jumper link removed
Grounding screw
3-Wire Conduit Connection -
Where Local Code Permits
4-Wire Conduit
Connection
(preferred)
Electrical Connection (cont.)
Connecting Conduit to the Range
WARNING
Do not connect the green appliance wire to the neutral (white)
supply wire unless local building codes permit.
1. Remove the range electrical access cover from the back of
the range.
2. IMPORTANT: If using a 4-wire connection, loosen the
grounding screw and remove the neutral to ground jumper
link from the terminal block. Leave the link in place for 3-wire
connections.
3. Remove the nut from the conduit strain relief (not included).
4. Slide the wires and the end of the strain relief into the hole on
the bottom of the range electrical box.
5. Before connecting the wires, slide the strain relief nut over
the wires and thread it onto the conduit strain relief inside the
box. Tighten into place.
6. Connect the white wire to the neutral terminal in the box.
7. Connect the black wire to the L1 power supply terminal.
8. Connect the red wire to the L2 power supply terminal.
9. If using a 4-wire connection, connect the green wire to the
grounding screw inside the box.
10. Replace the range electrical access cover.
Remove link on
4-wire installations
Terminal
block
Bare wire
connections
Loop and
spade terminal
connections