Frymaster 14 Series Fryer User Manual


 
7-3
7.2.2 Error Messages and Display Problems
Problem Probable Causes Corrective Action
M2007 display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option programmed.
Toggle between F° to C° by pressing
and holding 3and4simultaneously
until code appears. Enter 1658.
The computer displays OFF. Turn the
computer on to check temperature. If the
desired scale is not displayed, repeat.
M2007 display shows
hot-hi-1.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).
Shut the fryer down immediately and
call 1-800-551-8633 for assistance.
M2007 display shows
PROBE FAILURE.
Problem with the temperature
measuring circuitry including the probe.
Shut the fryer down and call 1-800-551-
8633 for assistance.
M2007 display shows
IGNITION
FAILURE.
Open drain valve, failed computer,
failed interface board, open high-limit
thermostat.
Verify that the drain valves are fully
closed. If this does not correct the
problem, call 1-800-551-8633 for
assistance.
M2007 display shows
PROBE FAILURE
with alarm sounding.
Damaged computer wiring harness or
connector.
Call 1-800-551-8633 for assistance.
M2007 display shows
igNITION
FAILURE
with alarm sounding.
Heating indicator is
on, but fryer is not
heating.
Drain valve not fully closed. Press the reset switch on the front of the
MIB box, located inside the filter
cabinet. All drain valves should close.
Turn the computer OFF and then ON
again. If the problem continues call 1-
800-551-8633 for assistance.
M2007 display shows
RECOVERY
FAULT and alarm
sounds.
Recovery time exceeded maximum time
limit.
Clear error and silence the alarm by
pressing the 9 button.
M2007 display shows
RECOVERY
FAULT call
service and alarm
sounds.
Recovery time exceeded maximum time
limit for two or more cycles.
Clear error and silence the alarm by
pressing the 9 button. Call 1-800-551-
8633 for assistance. Maximum recovery
time for electric is 1:40.
M2007 display shows
REMOVE
DISCARD.
In non-dedicated mode a product is
dropped that has a different setpoint
than the current vat temperature.
Remove and discard product. Press and
hold the cook button for three seconds
under the display with the error to
remove the error. Reset the setpoint of
the vat before trying to cook product.
Computer locks up.
Computer error. Call 1-800-551-8633 for assistance.
M2007 displays
CHANGE FILTER
PAD three times and
displays OFF.
No was chosen on previous CHANGE
FILTER PAD prompt or yes and no
were pressed consecutively.
Wait 15 minutes until CHANGE
FILTER PAD is displayed with
flashing lights. Change filter pad if
needed and ensure the pan is removed
from cabinet for at least TWO minutes.
Then press 9 (1 YES) to clear message.