3-3
2. Press the computer/controller ON/OFF switch to the ON position and set the thermostat or
program the computer for normal cooking temperature.
3. If the burners fail to light, press the ON/OFF switch to the OFF position and wait 60 seconds.
Repeat step 2.
4. The fryer will automatically enter the Melt cycle mode if the frypot temperature is below 180ºF
(82ºC). (NOTE: During the melt cycle, the burners will repeatedly fire for a few seconds, then
go out for a longer period.) When the frypot temperature reaches 180ºF (82ºC), the unit will
automatically switch to the Heating mode. The burners will remain lit until the frypot
temperature reaches the programmed cooking temperature.
5. After the burners have been lit for at least 90 seconds, observe the flames through the burner
viewing ports located on each side of the combustion air blower.
The optimum burn is a bright orange-red glow. If a blue flame is observed, or if there are dark
spots on a burner face, the air/gas mix requires adjustment. Adjustment procedures are different
for CE and Non-CE units.
Adjusting Air/Gas Mix:
Non-CE Units and CE Units Built After April 1999
On the side of the blower housing opposite the motor is a plate with one or two locking nuts.
Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open
or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in
position and tighten the locking nut(s).
Left
Viewing
Port is
Behind
Motor
Right
Viewing
Port