Frymaster h50 Fryer User Manual


 
6-8
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
C. Improperly installed or prepared
filter pan components.
Test: Close the drain valve.
Move the filter handle to the OFF
position, pull the filter pan (and
Power Shower, if so equipped)
from the unit. Move the filter
handle to the ON position.
If a strong stream of air is being
pumped out of the oil return port
(or the Power Shower port), the
problem is with the filter pan
components.
D. Remove the oil from the filter pan
and replace the filter paper,
ensuring that the filter screen is in
place under the paper.
If this does not correct the
problem, the filter tube suction
tube is probably blocked. Remove
the blockage using a thin, flexible
wire. If unable to remove the
blockage, call FASC.
(Continued from
previous page.)
D. Improperly installed or prepared
filter pan components.
Test: Close the drain valve.
Move the filter handle to the OFF
position, and pull the filter pan
(and Power Shower, if so
equipped) from the unit. Move
the filter handle to the ON
position.
If a strong stream of air is being
pumped out of the oil return port
(or the Power Shower port), the
problem is with the filter pan
components.
D. Verify that filter connection
o-rings are present and in good
condition.
Replace the filter paper, ensuring
that the filter screen is properly
positioned under the paper.
If using Magnasol filter assembly,
verify that o-ring is present and in
good condition on filter screen
fitting.
A. Plugged openings or solidified
shortening in the Power Shower.
Test: Look for oil/shortening
squirting out around the Power
Shower gasket but not coming out
of the holes around the frame. If
so, Power Shower is obstructed.
A. Clean the Power Shower per
instructions in Chapter 5 of this
manual.
B. Missing/worn o-rings and gasket
on Power Shower.
B. Verify that o-rings and gasket are
present and in good condition.
Power Shower is not
spraying properly.
C. Missing paper in filter pan. (This
causes too much pressure in the
oil return lines, resulting in a
strong flow through the Power
Shower, but also squirting of oil
from around the gasket.)
C. Verify that filter paper is properly
installed in the filter pan.