4-3
2. Remove used filter paper if present, and clean the pan as necessary. Verify that the metal filter
screen is in the bottom of the pan, and then lay a clean sheet of filter paper over the top of the
pan, overlapping on all sides.
3. Position the hold-down ring over the filter paper and lower the ring into the pan, allowing the
paper to fold up around the ring as it is pushed to the bottom of the pan.
4. Sprinkle filter powder over the filter paper. (For powder quantity, see the filter powder
manufacturer’s instructions.) Replace the crumb tray in the filter pan and close the cover.
5. Push the filter pan back into the fryer, positioning it all the way to the back of the cabinet.
(When the FM II filter assembly is properly positioned, the green HEATER ON indicator will
light.)