5-4
2. When the computer display shows a series of four dashes “----” with no dot between the first and
second dashes (indicating that the frypot contents are within the cooking range), press the
switch once to display the temperature of the cooking oil or shortening as sensed by the
temperature probe.
3. Press the
switch twice to display the set point.
4. Note the temperature on the thermometer or pyrometer. All three readings should be within
± 5ºF (2ºC) of each other. If not, contact a Factory Authorized Service Center for assistance.
QUARTERLY CHECKS AND SERVICE
Clean Combustion Air Blower Assembly
A sheet metal shield or shield assembly prevents inadvertent access to the blower assembly. The
specific design varies depending upon the particular configuration of the fryer and the country for
which manufactured, but in all cases the shield is attached to the cabinet framing by sheet metal
screws. Remove the screws that secure the shield or shield assembly to the cabinet framing and pull
the shield out of the fryer to expose the combustion air blower assembly.
1. Disconnect the blower wiring harness and remove the four blower mounting nuts.
2. Remove the three fasteners that secure the blower motor assembly to the blower housing, and
separate the two components.
Wiring connection
Blower
assembly
mounting nuts