6-9
6.5 Troubleshooting the Basket Lift
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Basket lift
movement is jerky
and/or noisy.
Basket lift rods need lubrication.
Lubricate basket lift rods with
Lubriplate™ or equivalent light white
grease.
6.6 Replacing the Ignition Module Fuse
1. Disconnect the fryer from the electrical supply and remove the two screws in the upper corners
of the control panel. Swing the panel open from the top, allowing it to rest on its hinge tabs.
2. Locate the 3-amp ignition module fuse (refer to the illustration below), and using a fuse-puller,
remove and replace it with a new fuse.
For units in which the ignition
module has no fuse, replace the
upper fuse on the interface board.
Depending upon when the unit was
manufactured, full vat units may have either
one or two ignition modules. If there is only
one ignition module, the fuse will be mounted
on the interface board.
Dual vat units and some full vat units will have
two ignigiton modules. Look for the fuse on
the left side of the module. If there are no
fuses on the modules, the fuse will be on the
interface board.
Ignition Module
3. Close the panel and replace the control panel screws.
4. Reconnect the fryer to the electrical supply.