3 Operation
Determination of pump capacity, Pump Unit B
– Leave speed selector switch setting unchanged.
– Leave volume ratio setting of 1:1 unchanged.
Proceed analogously and in a mirror inverted manner, as described above for
Determination of pump capacity, Pump Unit A.
Determination of calibration factor
Example for calibration factor calculation:
X = amount of product A discharged 10 grams
Y = amount of product B discharged 11 grams
Fill measuring cup (30 – 50ml) one third full with water, dispense and read off
the amount discharged.
Formula: X/(Y:100) = calibration factor 10/(11:10) = 90.9 %
For the description how to enter the calibration factor go to Section 3.8.5.