67
3 Operation
3.7.1 Volume ratio
Setting reflects output of Pump Unit A vs. Pump Unit B. The output amount of
pump B is the reference value and is assigned a factor of 1.
The volume ratio setting is indicated in the Operation display.
Volume ratio setup:
With the dispensing station in ready state, push OK button - display indicates
volume ratio.
Use arrow keys to enter desired value.
Arrow key assignment / setting range:
left: -0.5; right: +0,5; up: +0,05;
down: -0,05; setting range: 1.0 – 6.0
• Push OK button to save the setting – display indicates "next menu item". Push
ESC key to leave the operator menu – display indicates Operation.
For volume ratio setup refer to and follow exactly the instructions on product
containers.
OK/ESC
A:B 1.00:1 100%
*