5 Maintenance
5.3.2 Disassembling the pump – Removing the stator
Position the pump unit in a vise so that the jaws clamp on the mounting flange (1).
Do not loosen the clamp ring (2). Pump (a) must remain connected to
gearbox/motor (B).
Unscrew vent screw (5).
Unscrew 3x clamp nuts (3) of compression screws (4) together with sealing
ring (6).
Remove follower plate (7).
Back off screw (8) (anti-twist feature) a few turns.
Remove the stator (9) by twisting and pulling in direction of arrow until it comes off
the rotor assembly.
5.3.3 Replacing the wiper ring
Loosen the clamp ring (2) and pull Pump (A) off the drive motor (B).
Unscrew vent screw (5).
Unscrew 3x clamp nuts (3) from two-part follower plate (7).
Pull off follower plate and disassemble.
Separate the two follower plate sections and replace wiper ring (10) by a new one.
Replace gaskets of clamp nut (3) and vent screw (5).
Re-assemble in reverse order.