PROG
START
PROG
START
34
Operation and settings
■ Turn unit on.
■ Load oven rack.
■ Insert probe into thickest part of meat, or into central location of other types
of foods, on center oven rack.
NOTE: Be sure IQT Sensor is clean and cool prior to insertion.
■ DO NOT select cooking mode. Deactivate if mode has already been selected.
■ Press IQT key: “+PROFILE” appears in the adjacent display.
■ Press PROG/START key to activate program.
■ “BROWN 4” appears in the temperature display. While the figure 4 is flashing,
use Central Dial to select desired level of browning from 1 to 7 (light to dark).
■ The IQT Sensor display shows a pre-selected core temperature of 162°F (72°C).
Press the IQT Sensor key and use Central Dial to set the desired core temperature.
■ Press PROG/START to confirm and initiate +Profile cooking.
During operation
■ Since all modes and humidity levels are enabled by the automated process, the
ClimaPlus window will display a blue-red bar and Moist Heat and Dry Heat
modes will be active during the entire cooking cycle.
■ Cook time remaining is displayed and constantly updated during the latter stages
of the cycle.
■ Actual core temperature is displayed next to selected “Done” temperature.
■ The control panel is not accessible during operation to prevent automatically
selected settings from being accidentally altered. HACCP, Half Energy and Half
Speed Fan functions can be selected during operation.
■ Opening the door during operation merely interrupts the cooking process.
When door is closed, all functions resume.
■ To stop any IQT program altogether, it is necessary to turn off the unit.
NOTE: +Profile is a complete cooking program that automatically controls
the cooking process. It cannot be used as a step in another program. However,
IQT +Profile can be saved with specific settings as an individual custom program
(See Programming, page 43.)
COOKING
FUNCTIONS
IQT
+
PROFILE
continued
+PROFILE
BROWN 4
162