Henny Penny LCS Fryer User Manual


 
60
Unit weights:
LCS 6: 270 lbs. (123 kg) LCG 6 335 lbs. (152 kg)
LCS 10 334 lbs. (152kg) LCG 10 384 lbs. (174 kg)
LCS 1020 484 lbs. (220 kg) LCG 1020 584 lbs. (265 kg)
LCS 20 686 lbs. (312 kg) LCG 20 798 lbs. (362 kg
LCS 40 972 lbs. (442 kg) LCG 40 888 lbs. (403 kg)
6) Installation models 6, 10, 1020
Place floor stand at the installation place and level by adjusting legs. (Fig. 3).
Minimum clearance required to neighboring equipment or walls. (page 59)
Place the unit on top of the stand. The units legs must be centered on
the locating pins of the stand (Fig. 4).
Unit must be level (Fig. 5).
7) Installation models 20, 40
The unit must be secured against shifting on the floor by means of floor
fixtures (Fig. 6). If floor fixtures are glued to the floor (use polyurethane
glue or similar), remove all grease from the floor first.
Place the unit at its final location and level by adjusting legs. (Fig. 5).
Minimum clearance required to neighboring equipment or walls. (page 59)
The area of floor under the unit where Mobile Oven Racks will roll in
must be level or door will not seal. (Fig. 7).
Electrical
8) Electrical connection
Connect the unit only according to the information given on the data plate.
Observe all regulations of your local Electrical Code.
The appliance may only be connected by a licensed electrician.
Each appliance requires an independent fused power supply line.
Connection via GFI circuit breaker is advisable.
On-site installation: provide accessible all-pole disconnection device with
minimum of
1
8 in. (3 mm) contact gap (not required for 120v gas units.)
Connect appliance to ground.
Special voltages on request. Circuit diagram is located behind the operator
panel.
Connected load for electric units:
INSTALLATION
continued
Model KW
Amps
208v 3Phase 240v 3 Phase 208v 1 Phase 240v 1 Phase
LCS-6 10 28 24 48 42
LCS-10 19 53 45.8
LCS-1020 31.5 87.5 75.9
LCS-20 38 105.6 91.5
LCS-40 63 175.1 151.8
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7