Hobart F-40182 Oven User Manual


 
PROGRAMMING, ALL SOFTWARE VERSIONS
Parameter
Number
Description KA7E KA7EM
1
0 = Fahrenheit. F 0 will display in Time window. Default = 0
1 = Celsius. C 1 will display in Time window.
FC will display in Program window.
If the temperature display option is changed, you will see a slight pause as all
stored cook programs are converted to new units.
X X
2
0 = AM/PM. AP 0 will display in Time window. Default = 0
1 = 24 hour clock. 24 1 will display in Time window.
CL will display in Program window.
X X
3
Future use - To be used when connected to remote computer.
0 = ASCII serial protocol. 0 will display in Time window. Default = 0
1 = Binary serial protocol. 1 will display in Time window.
SP will display in Program window.
X X
4
Future use - To be used when connected to remote computer.
Oven ID number Range = 0 to 31. The number entered will display in Time window.
Default = 0
ID will display in Program window.
X X
5
Temperature offset. Difference between sensor temperature and displayed
temperature value; used to correct for the difference between sensor and cooking
chamber temperature if any.
Range = +30 to -30. The number entered will display in Time window. Default = 0
C or F depends on unit selected.
OS will display in Program window.
X X
NOTE: In the table below, an asterisk (*) beside
Parameter Number indicates a Service Only
parameter that must be unlocked to verify or edit the
setting as outlined in the following procedure. After the
unlock code is entered, any of the Service Only
parameters are viewable.
1. Press 72 and select ENTER (parameter to unlock
service only parameters.
2. Press 1972 and select ENTER (code to unlock
service only parameters) (1 beep).
3. Enter desired Parameter Number containing an
asterisk (*) and verify or edit the setting as
necessary.
4. After all desired Parameter Numbers are
checked, press 0 (zero) and select ENTER.
Normal programming can continue.
5. Verify the remaining Parameter numbers as
necessary.
PROGRAMMING CONTINUED, CURRENT SOFTWARE VERSION C027
Parameter
Number
Setting Description KA7E KA7EM
31 43
Chemical pump ON time in seconds (default = 43). Time required may
vary for type of chemical used.
CP will display in Program window.
X ---
KA SERIES ELECTRIC ROTARY OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
Page 37 of 72 F25294 Rev. A (0412)