Hobart F-40182 Oven User Manual


 
PROGRAMMING CONTINUED, CURRENT SOFTWARE VERSION C027
Parameter
Number
Setting Description KA7E KA7EM
*32 10
Preheat time in minutes (default = 10)
PH will display in Program window.
X X
*33 2
Main Drain pump ON time in minutes (default = 2)
SP will display in Program window.
X ---
34 120
Chemical wash time in minutes (default = 120)
Ct will display in Program window.
X ---
35 2
Number of rinse cycles (default = 2)
nr will display in Program window.
X ---
*36 2
Rinse time in minutes (default = 2)
Rt will display in Program window.
X ---
37 1
Number of pre-rinses (default = 1).
nP will displayed in Program window.
Increase pre-rinse number if initial fill is not hot enough.
X ---
38 0
Leave setting at 0 and advance to next program number.
Ft will display in Program window.
X ---
39 0
Leave setting at 0 and advance to next program number.
LC will display in Program window.
X ---
*40 5
Water fill time limit in minutes (default = 5)
FL will display in Program window.
Add time as necessary if water pressure is low.
X ---
*41 150
Cool down temperature in Fahrenheit (default = 150)
Ct will display in Program window.
Oven must cool to this temperature before next operation can start.
X X
*42 150
Preheat temperature in Fahrenheit (default = 150)
CP will display in Program window.
X X
*43 200
Drying temperature in Fahrenheit (default = 200)
Cd will display in Program window.
X ---
44 0
Demo Mode. Leave setting at 0 (zero) and continue to the next
Program Number. See DEMO MODE in the next section.
dE will display in Program window.
X ---
*45 15
Additional fill time in seconds (default = 10)
0F will display in Program window.
X ---
48 4
Wash pump ON time during cleaning (default = 4)
Pr is display in Program window.
X ---
49 4
Wash pump OFF time during cleaning (default = 4)
SO will display in Program window.
X ---
KA SERIES ELECTRIC ROTARY OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
F25294 Rev. A (0412) Page 38 of 72