Hobart F-40287 Oven User Manual


 
Fig. 31
4. To remove strain pan support, lift end and
disengage other end from stud.
Fig. 32
5. To remove drain shroud, remove nuts and
washers securing shroud and lift shroud out of
oven.
Fig. 33
6. Reverse procedures to install.
LAMP
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Do not touch the glass portion of the lamp
with your hands. The oil from your hands could affect
the operation of the lamp. Skin oil may be removed
with alcohol while the lamp is cold.
NOTE: Use a clean rag or paper towel to handle
replacement lamp.
1. Open door.
2. Remove screws securing facade to oven.
Fig. 34
3. Remove two nuts securing lamp assembly to top
of oven.
Fig. 35
4. Lift lamp assembly out of oven and support it.
5. Loosen screws in terminal block securing lamp
wires and pull wires out of block.