Hobart F-40287 Oven User Manual


 
PERISTALTIC PUMPS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Oven cleaners are corrosive and
can cause chemical burns. Rubber gloves, goggles
and protective clothing are required. Read and follow
the instructions for the oven cleaner.
NOTE: Procedure applies to KA7E; and the KA7EM
with grease assist only.
NOTE: KA7E rotisserie ovens previously were
produced with 3 peristaltic pumps - a gray water/sump
pump, grease pump, and chemical pump. The gray
water/sump pump is no longer required in current
production beginning with Serial No. 46300096. The
pump system parameters have changed so that the
main drain pump (not pictured) removes any lingering
gray water from the sump. Refer to
SERVICE MODE
- PROGRAMMING AND DIAGNOSTICS for
Programming parameters
Fig. 81
TSB 1417 KA7E - CLOGGING AT INPUT AND
OUTPUT OF PERISTALTIC PUMPS. See Multimedia
section in TIS.
Pump Removal
1. Remove Right Side Cover.
2. Disconnect wires for pump to be removed.
3. Disconnect hoses for pump to be removed.
4. Remove screws securing pump to frame.
Fig. 82
5. Rotate pump slightly counterclockwise to line up
with cutout in frame and withdraw pump out of
frame.
Fig. 83
6. Reverse procedure to install.
Procedure to Replace Pump Hose
NOTE: Only use recommended replacement hose
found in the parts catalog.
1. Remove three screws securing face plate and
pull face plate off.
KA SERIES ELECTRIC ROTARY OVENS - REMOVAL AND REPLACEMENT OF PARTS
F25294 Rev. A (0412) Page 26 of 72