hussman P/N 0420057_B Refrigerator User Manual


 
From the back of the case, hang the coil cover
from the top hooks, then position the drip tray in
the case with the drip tube connection to your
right. Hang drip tray on two back hooks and two
front hooks.
Connect installed copper drip tube to drip tray
using flexible connector supplied.
Ensure condensate flows freely from drip tray
through drip tube. Check the drip tube connec-
tion for leaks before stocking.
R
EMOVING PROTECTIVE FILM FROM BUMPER
Remove protective film from bumper once
installation is complete.
Installing Optional Wrap Board
MOA 0470438
1. Turn off power to case.
2. Determine location by positioning the wrap
board on the rear of the case between door
frames.
P/N 0420057_B 1-9
Service Merchandisers
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Coil
Drip Tray
Coil
Cover
Drip Tray Hooks
Drip Tray Hooks
Coil
Cover
Hooks
Front Back
Drip Tray
Drip Tube
Connector
7.562
7.874 7.874 7.562
Rear View of Case - Location of Backups
36.717 36.71740.19312-Ft
8-Ft
6-Ft
4-Ft
36.668
36.668
33.125
24.656
24.656
19.327
TYP
2.668
TYP
Notes:
1. All dimensions given in inches.
2. For location of Backups on cases with add-on wedge, start measuring from
the square end of the case opposite the wedge end. Use corresponding case
size dimensions.
3. For location of Backups on 7-Ft cases (facing rear of case)
use 6-Ft case dimensions on the left and 8-Ft case dimensions on the ri
g
ht.
Backup