INSTALLING SPLASHGUARD AND
LOWER FRONT PANEL
Make certain that the end assemblies, end
splashguards and end panels have been
installed according to the End Kit instruction.
The splashguard and lower front panel are
shipped inside each case. After merchandisers
have been leveled and joined, and all drip
piping, electrical and refrigeration work has
been completed, install the splashguard and
lower front panel.
1. At front of merchandiser, attach a splashguard
retainer/bracket to each leg with sheet metal
screws.
2. Position top of splashguard over the top edge
of the retainer/bracket as shown below.
3. Push the lower edge of the splashguard toward
the bottom of the bracket until it snaps into
place.
To Install Lower Front Panel
1. Position the lower front panel with the top
angled as shown in the illustration. Tabs
extending from the upper front assembly are
designed to fit into the slots on the top of the
lower front panel.
2. Once the top is positioned, lift the panel up
and drop it into the groove at the top of the
splashguard.
Do not use additional fasteners or sealant to hold
splashguards or panels in place. To meet NSF
cleanability requirements, splashguards and
panels must be removable without tools.
3-2 DRIP PIPING AND SPLASHGUARDS
P/N 0420057_B
U.S. & Canada 1-800-922-1919 • Mexico 1-800-522-1900 • WWW.HUSSMANN.COM
Splashguard
Leg of
Case
2
Leg of
Case
Splashguard
3
Tab
Lower
Front
Panel
Lower Front Panel
Retainer/
Bracket
Leg of
Case
Leg of
Case
1
1
2
Leg of
Case