hussman P/N 0420057_B Refrigerator User Manual


 
Installing Optional Scale Stand
MOA 0458960
1. Turn off power to case.
2. Determine location by positioning the scale
stand on the rear of the case between door
frames.
3. Using holes in scale stand bracket as a
template, mark hole locations on rear and top of
case.
4. Remove scale stand. Drill
1
/8-inch diameter
pilot holes through metal liners at the marked
locations.
NOTE: M
ETAL LINERS ARE LESS THAN
1
/
8-INCH
THICK-- DO NOT DRILL BEYOND METAL LINERS.
5. Move top panel away from back of case.
Remove center rear door trim and remove LH
Upright wireway cover to allow routing of
receptacle harness.
P/N 0420057_B 1-11
Service Merchandisers
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Screw - SM #8-18 x
3
/8 Hex Head
Rear Door Center Trim
Communication Cable
Route cable with 12-in.
outside the strain relief
connector in the scale stand
3/4 Bushing
LH Upright
Wireway
Harness -
Receptacle
Scale Stand Upright Cover
(2 required)
Insulation in this area to be notched
as needed for wire harness routing.
Convenience Outlet
Connect after routing wiring through case.
Isolated Ground Sticker
Screw - SM #8-18 x
3
/8
Truss Head
(3 required)
Install strain relief connector where
Communication Cable exits scale
stand assembly. Use plug button if
Communication Cable i not required.
(If required)
Case Wireway
Screw - SM #8-18 x
3
/8
Truss Head