Cornelius R-134A Beverage Dispenser User Manual


 
312027000
33
WATER LINE TO TANK
DOUBLE-LIQUID
CHECK VALVE
WHITE TAPERED GASKET
ELBOW
PUMP TO MOTOR COUPLING
WATER PUMP
WATER
STRAINER SCREEN
(P/N 315348000)
O-RING (P/N 315349000)
SCREEN RETAINER
FIGURE 9. WATER STRAINER SCREEN AND DOUBLE-LIQUID CHECK VALVE
8. Connect the carbonated water line to the double-liquid check valve.
9. Turn the carbonator primary CO
2
regulator adjusting screw to the right (clockwise) until its gage indicates
pressure setting noted in step 4 of Servicing Water Pump Water Inlet Strainer Screen.
10. Open the water inlet supply line shutoff valve.
11. Pull up on the carbonated water tank relief valve to purge all air from the tank.
12. Install the carbonated water tank access hole cover and secure with screw.
13. Install the Unit hood and secure with screw.
14. Plug Unit power cord into electrical outlet.
15. Test dispense Unit for proper operation.
REPLENISHING CO
2
SUPPLY
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.