Cornelius R-134A Beverage Dispenser User Manual


 
44
312027000
Trouble Probable Cause Remedy
DISPENSED PRODUCT
PRODUCES FOAM AS IT
LEAVES DISPENSING
VALVE.(CONTD)
F. Dirty water supply. F. Check water filter. Replace
cartridge (see NOTE).
NOTE: If water supply is dirty, be sure to flush lines and carbonator
completely. It may be necessary to remove lines to carbonator tank,
invert tank, and flush the tank and all inlet lines to remove any
foreign particles or dirt.
NO PRODUCT DISPENSED
FROM ALL DISPENSING
VALVES.
A. Dispensing valves keyed
lock-out switch in OFF
position.
A. Place keyed lock-out switch in
ON position.
B. Power switch (if applicable) in
OFF position.
B. Place power switch in ON
position.
C. No electrical power to Unit. C. Plug in Unit power cord or check
for blown power fuse or tripped
circuit breaker.
D. Inoperative power switch (if
applicable).
D. Replace power switch.
E. Dispensing valves power cord
disconnected.
E. Connect dispensing valves power
cord.
F. Disconnected or broken wiring
to dispensing valve.
F. Connect or replace wiring.
G. Inoperative transformer or
valve solenoids.
G. Replace inoperative part.
ONLY CARBONATED WATER
DISPENSED.
A. Out of syrup. A. Replenish syrup supply as
instructed.
B. Inoperable dispensing valve.. B. Repair dispensing valve.
C. Dispensing valve syrup flow
control not properly adjusted.
C. Adjust dispensing valve syrup
flow control as instructed.
D. Dispensing valve syrup flow
control or syrup lines
restricted.
D. Sanitize syrup system as
instructed.
ONLY SYRUP DISPENSED. A. Water inlet supply line shutoff
valve closed.
A. Open water inlet supply line
shutoff valve.
B. Carbonator power cord (under
hood) unplugged.
B. Remove hood and plug in
carbonator power cord.
C. Carbonator CO
2
regulator not
properly adjusted.
C. Adjust carbonator CO
2
regulator
as instructed.
D. Inoperative carbonated water
tank liquid level control
assembly.
D. Replace carbonated water tank
liquid level control assembly.
E. Inoperative water pump, water
pump motor, or water pump
power switch.
E. Replace inoperative component.