Locke RS-5100 Kitchen Utensil User Manual


 
Wiring The 5100 Sharpener
THIS SHOULD BE DONE BY AN EXPERI-
ENCED, LICENSED ELECTRICIAN.
Wire the sharpener to a 20 amp, 220 volt
breaker equipped with a disconnect. The elec-
trical junction box is located in the upper center
area inside the front panel.
IMPORTANT
Disconnect all power during routine mainte-
nance and when the sharpener will be out of
service for extended periods of time.
Electrical Wiring Source To Front
Panel Models –220 Volts
1. Unfasten the front panel on the control box and swing the door open.
2. Locate the disconnect. It is the black plastic switch located on the top center of
the box.
3. Remove the screw A and slip off the cover.
4. Connect a 110V lead to the L1 position and a 110V lead to eh L3 position.
5. Connect the ground wire to the same position as the machine ground (the green/
yellow wire).
6. Replace the protective cover.
7. Close and secure the front panel.
DANGER
678E EE910
A
N
T1 T2
T3
L3L2
L1
LINE 110 VOLTS
LINE 110 VOLTS
GROUND
10