Locke RS-5100 Kitchen Utensil User Manual


 
Electrical Wiring Source To Front Panel Models—240 volts (Foreign)
1. Unfasten the front panel on control box and swing the door open.
2. Locate the disconnect. It is the black plastic switch located on the top center of the box.
3. Remove screw A and slip off the cover.
4. Connect a 0V lead to the neutral position and the 240V lead to the live position.
5. Connect the ground wire to the same position as the machine ground (the green/yellow wire).
6. Replace the protective cover.
7. Close and secure the front panel.
Coolant
1. Check the coolant reservoir and remove any foreign
objects.
2. Be sure the drain hose is routed through the hole in
the lid of the coolant tank.
3. Fill the tank with clean water, adding the proper
amount of anti-rust additive. Recommended mixture
ratios are between 50:1 and 25:1.
FAILURE TO USE AN ANTI-RUST ADDITIVE
MAY DECREASE THE SERVICE LIFE OF
SOME PARTS! NEVER USE WATER ONLY,
AND DO NOT USE WATER SOLUBLE OIL.
CAUTION
678E EF910
A
NE
T1 T2
T3
L3L2
L1
LIVE 240 VOLTS
NEUTRAL 0 VOLTS
NEUTRAL 0 VOLTS
LOAD
11