Maytag ACO1860AS Microwave Oven User Manual


 
Disassembly Procedures
To avoid the risk of electrical shock, personal injury or
death; disconnect power to oven and discharge
capacitors before following any disassembly procedure.
WARNI NG
!
©2002 Maytag Appliances Company 19 16021668 Rev. 0
Control Panel
The control panel is made up of several components,
such as p.c. board and touch panel.
Control Panel Removal
1. Disconnect oven power and remove grille, (see
"Grille" section).
2. Remove screw located at the top of touch panel. Lift
control panel up and out to release bottom tab
connections.
3. Place control panel on a flat surface.
4. Reassemble in reverse order.
P.C. Board
The p.c. board is located at the top on back of control
panel. Some boards has up to five connection plugs
which control the following:
CN1 Main power connector
FPC (S1) Ribbon connector for key panel
Relay 7 Relay connector
Power
Transforme
r
Relay 7
Control Pan
el
Screw
F
PC (S-1)
c
onnector
CN1
Circuit
Board
ACO1520*, ACO1530*, and MMV5156*
6. Remove door handle by placing a hand on door panel
next to the top of the door handle. Twist door panel
towards the inside of door and pulling on the top
portion of the door handle in a quick jerking motion.
NOTE: When replacing door handle, the bottom portion
of the door handle must be inserted first.
7. Slide door glass to the right slightly, then push the
door glass upward to release the glass from the
track.
8. Reassemble in reverse order.
Door
glass
Latch
assemb
ly
Spring
Choke
cover
Screw
Tape
seal
Door
frame
Door
panel
Door
handle
CAUTION
!
Once outer door trim panel is removed the glass
panel is loose.
CAUTION
!
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembly,
or adjusted for any reason.