Maytag ACO1860AS Microwave Oven User Manual


 
Installation Instruction
16021668 Rev. 0 A–2 ©2002 Maytag Appliances Company
Proper installation is the installer’s responsibility!
Write the model & serial numbers on the owner’s
manual. The model number label is located on the oven
front.
Model Number Label
The mounting plate is located on the back side of the
microwave oven.
Mounting
plate
(
Remove from
back of oven)
The dimensions of the oven are as follows:
ACO15* Models ACO18* Models
Height : 16
7
/16 in. 16
7
/16 in.
Width : 29
15
/16 in. 29
15
/16 in.
Depth : 15
3
/8 in. 15
1
/2 in.
Weight : 52 lbs. 60 lbs.
CAUTION
!
To avoid risk of personal injury two people are
required to install this oven.
Avoid Electrical Shock!
Before you drill into the wall, note where electrical
outlets are and where electrical wires might be
concealed behind the wall. YOU COULD GET AN
ELECTRIC SHOCK if you contact electrical wires
with your drill bit.
Locate and disconnect the power to any electrical
circuits that could be affected by installing this oven.
IF YOU DO NOT DISCONNECT THE POWER,
YOU COULD GET AN ELECTRIC SHOCK.
Electrical rating of this oven: 120V AC 60Hz.
13 A / 1500 W (Microwave oven, Cooktop Lamps,
Ventilation Fan)
You need a DEDICATED 120VAC / 60Hz / 20A, fused
electrical supply (located in the cabinet above the
microwave as close as possible to the microwave)
serving only the microwave.
WARNING
!
To avoid risk of electrical shock, personal injury or
death; do not use the grounding plug improperly.
Check with a qualified electrician if you are not sure
whether the oven is properly grounded or if you do not
completely understand the grounding instructions.
Do not use a fuse in the neutral or grounding circuit.
Save these instructions for the local electrical
inspector’s use.
This appliance MUST be grounded!
If there is an electrical short circuit, grounding
reduces the risk of electrical shock by providing an
escape wire for the electric current. This appliance
is equipped with a cord having a grounding wire with
a grounding plug.
Place the plug into a properly installed and grounded
outlet.
Do not use an extension cord.
Keep the power cord dry and do not pinch or crush.
Do not, under any circumstances, remove the power
supply cord grounding prong.
Properly Polarized and
Grounded Outlet
Three-Pronged (Grounding) Plu
g