Maytag AOCS3040 Oven User Manual


 
Component Testing Information
!
WARNING
To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless
testing requires it.
16021875 Rev. 0 ©2003 Maytag Appliances Company
12
Illustration Component Test Procedure Results
ERC4800 Controlled
Child lock out This is a safety feature that can be
used to prevent children from
accidentally programming the oven. It
disables the electronic oven control.
Press and hold Bake and Cook Time
for 10 seconds. “OFF” will display
where the temperature normally
appears.
To reactivate the control, press and
hold Bake and Cook Time for 10
seconds. Child lockout features must
be reset after a power failure.
E17
E16
E11
E10
E13
E12
E18
E3
E2
E14
E15
E6
E7
E8
E9
E4
E5
E19
K10
K11
K4 K2
K5
K6
K3
K1
Oven
Light
Panel
Light
Bake
Broil
Conv.
Element
Door
Lock
Conv.
Fan
Double
Line Brk
E1
Relay board Listen for relay to actuate.
Verify input and output power.
If relay does not actuate, verify power to
relay.
ERC/Adapter board
assembly
F1 - Control malfuction. Replace ERC.
Field Selectable Options
Standard: The standard setup is 8. This is a 12 hour type of clock, 60 Hz line frequency and an oven with a
convection fan.
Clock Time Format 12 or 24 hour format
The time of day and the stop time can be displayed in either a 12 or 24 hour format. The control will come in a 12
hour format and can be changed to a 24 hour format from the front control panel.
Clock Time Base 60 or 50 Hz input line frequency
This is a time reference for the clock, timer, and internal timing of the control. The control will select the frequency
automatically when the control is powered up.
Selecting Options
In order to select the field selectable options, Press and hold the CLOCK pad on power up of the control. To change
the options press one of the slew pads until the desired option appears and in approximately 9 seconds the control
will change to the normal operation or once selected press the CANCEL pad. The right time digit will indicate the
current options selected as listed in the table below. (Standard setting is 8.)
Code Number 24 Hour Clock 50 Hz No Convection Fan
8
9 X
H
X
r X X
o
X
d X
X
X X
Blank X X X
X = indicates Selected = indicates Not Selected