Component Testing Information
!
WARNING
To avoid risk of electrical shook, personal injury or death: disconnect power to oven before servicing, unless
testing requires it.
©2003 Maytag Appliances Company 16021875 Rev. 0
13
Element Conditions
Relay drive requirements are defined as a percentage of on time based on a 60 second cycle.
Bake .......................First rise to temperature = 100% bake, 50% broil, then 100% bake, 25% broil
Broil........................100% broil, 0% bake
Clean ......................100% broil, 25% bake
Convection ............First rise to temperature = 100% bake, 50% broil, then 100% Convection element
For convection bake or convection broil refer to bake and broil specifications
Continuity is indicated as 100Ω and below. Each pad must be pressed to perform the following test.
J1 - 2
J1 - 20
J1 - 1
J1 - 6
J1 - 7
J1 - 5
J1 - 4
J1 - 3
J1-14
J1-13
J1-12
J1-11
J1-10
J1-9
J1-8
J1-16
J1-18
J1-19
BAKE
BROIL
TIMER
CLOCK
CLEAN
STOP
TIME
OVEN
LIGHT
CANCEL
SLEW
DOWN
SLEW
UP
COOK
TIME
Switch Matrix for AOES3030
J1 - 2
J1 - 20
J1 - 1
J1 - 6
J1 - 7
J1 - 5
J1 - 4
J1 - 3
J1-14
J1-13
J1-12
J1-11
J1-10
J1-9
J1-8
J1-16
J1-18
J1-19
BAKE
1
BROIL
1
TIMER CLOCK
CLEAN
1
CONV
1
CONV
BAKE
1
CONV
BROIL
1
STOP
TIME
OVEN
LIGHT
PANEL
LIGHT
CANCEL
1
SLEW
DOWN
SLEW
UP
COOK
TIME
1
Switch Matrix for AOCS3040
Control
Panel
Ribbon Cable
Pin 1 is located at the
bottom of the connector.
Top
Bottom