Maytag DN3000 Refrigerator User Manual


 
PROGRAMMING
19
of 90
“STOP HR” - Stop Hour and Minute Setting
This function is used to set the hours and minutes to stop light conservation and can be set in the
same manner as Start Hour and Minute Setting.
Press key number 1 to return to “STOP TIM”.
Press key number 1 to return to “LIGHTING”.
Press key number 2 to scroll to next routine.
*”REFRIG” - REFRIGERATION ROUTINE
This function is used to electronically control the refrigeration operations of the vender. Press key number 4 will
enter “ENABLE X”.
“ENABLE X” - Energy Conservation Enable Routine
This function is used to disable Energy Conservation “ENABLE 0” or enable Energy Conservation
“ENABLE 1”. When enabled the cabinet temperature will be allowed to rise to the programmed storage
level (“STORAGE”) during the following programmed time blocks.
Press key number 4 and the current “ENABLE X” setting will be displayed.
Press key number 2 or 3 to scroll between “ENABLE 0” and “ENABLE 1”.
Press key number 4 with the display showing the setting you wish to use.
Press key number 2 to scroll to “STRT TIM”.
“STRT TIM” - Start Energy Conservation
This function is used to set the days and time to start Energy Conservation when “ENABLE1” is selected.
Press key number 4 and “STRT DAY” will show on the display.
“STRT DAY” - Day to Start Setting
This function is used to set the days of the week to start Energy Conservation.
Press key number 4 and “XXXXXX#: will show on the display, where XXXXXX will be the day of the
week (i.e. MONDAY, TUESDAY, WEDDAY, THUDAY, FRIDAY, SATDAY, SUNDAY, EVRDAY) and
# is 0 = disable, 1 = enable. With the display showing the day you wish to set press key number 4.
The # will start blinking. Press key number 2 or 3 to scroll between “XXXXXX0” and “XXXXXX1”.
Press key number 4 with the display showing the setting you wish to use. Display will return to
“XXXXXX#”. Press key number 2 to scroll to the next day to set or press key number 1 to return to
“STRT DAY”.
Press key number 2 to scroll to “STRT HR”.
“STRT HR” - Start Hour and Minute Setting
This function is used to set the hours to start Energy Conservation.
Press key number 4 and “hhmm” will show on the display, where “hh” is the hour (military time) and
“mm” is the minute. “hh” will be blinking, indicating the hour setting may be changed. Press key
number 2 to scroll from 00 to 23. With the display showing the hour you wish to start Energy
Conservation, press key number 4. “mm” will start blinking, indicating the minute setting may be
changed. Press key number 2 to scroll from 00 to 59. With the display showing the minute you wish
to start Energy Conservation, press key number 4. The display will return to “STRT HR”.
Press key number 1 to return to “STRT TIM”.
Press key number 2 to scroll to “STOP DAY”.
“STOP TIM” - Stop Energy Conservation
This function is used to set the days and time to stop energy conservation when “ENABLE 1” is selected.
Press key number 4 and “STOP DAY” will show on the display.
“STOP DAY” - Day to Stop Setting
This function is used to set the days of the week to stop energy conservation and can be set in the
same manner as “STRT DAY” and “STRTHR”.
“STOP HR” - Stop Hour and Minute Settings
This function is used to set the hours and minutes to stop energy conservation and can be set in the
same manner as “START HR”.
Press key number 1 to return to “STOP TIM”.
Press key number 2 to scroll to “DEGREES”.