Maytag DN3000 Refrigerator User Manual


 
MAJOR COMPONENT DESCRIPTION
30
of 90
MAJOR COMPONENT DESCRIPTION
AC DISTRIBUTION BOX
110 VAC
15 Amp Outlet (110 VAC) Provides power to
refrigeration unit.
Transformer (T1) Provides 24 Volt
and 12 Volt (center
tap) power to the
Controller Board.
Fuse (Top) 10 Amp, 32 Volt,
SloBlo; protects 24
Volt input to
Controller Board
from secondary of
T1.
Fuse (Bottom) 2 Amp, SloBlo;
protects 12 Volt
input to Controller
Board from
secondary, center
tap of T1.
Varistor Across incoming
AC power to
remove large power
spikes.
Choke (Domestic) Foster
A-16015-01
5mH 6A.
Choke (Export) Foster
A-160405
5mH 6A (220Volts)
REFRIGERATION UNIT
110 VAC
Compressor Aspera, 1/2 HP, 115 VAC,
60 Hz, 1 Phase
T6213Z
Unit uses 13 oz. of 134A
refrigerant
Start Relay 110 VAC - T1 9660-041-180
Double Pole, 115 VAC
Start Capacitor 110 VAC - 189227
Thermal Overload 110 VAC - T1 MST16AFN-
3001
Condenser Fan 16W Motor
110 VAC
FV100CW25S
Blade - 10” dia.
Evaporator Fan Motor
110 VAC - SPGE9HBV1
Blade - 8” dia.