“DEGREES” - Degree Fahrenheit / Celsius Setting Routine
This function is used to set the degree reading to Fahrenheit (DEGREESF) or Celsius (DEGREESC).
Press key number 4 and “DEGREESX”, where the current setting (X) will be blinking. Press key number
2 or 3 to scroll between DEGREESF and DEGREESC.
Press key number 4 with the display blinking the setting you wish to use.
Press key number 1 to return to “DEGREES”.
Press key number 2 to scroll to “SETPOINT”.
“SETPOINT” - Set Point Control Routine (Default Temperature 35.0
0
F / 1.5
0
C)
This function is used to set the average product temperature for initial pull down and reload recovery.
Press key number 4 and “tt.tx” will show on the display where x is F (Fahrenheit) or C (Celsius) and tt.t is
the degrees.
Press key number 2 to increase or 3 to decrease the number by 1
0
F or 0.5
0
C. With the display showing
the set point temperature you wish to use, press key number 4.
Press key number 2 to scroll to “STORAGE”.
“STORAGE” - Storage Setting Routine (Default Temperature 60.0
0
F / 15.5
0
C)
This function is used to set the temperature for product storage and is used when Energy Conservation is
enabled.
Press key number 4 and “tt.tx” will show on display when X is F (Fahrenheit) or C (Celsius) and tt.t is the
degrees.
Press key number 2 to increase and 3 to decrease the number by 1
0
F or 0.5
0
C. With the display showing
the storage setting you wish to use, press key number 4.
Press key number 2 to scroll to “DISPLYX”.
“DISPLYX” - POS Temperature Display Enable Routine
This function is used to enable the POS Temperature to be displayed following the “ICE COLD COCA
COLA” POS message.
Press key number 4 and “ DISPLYX” will show on the display where x is the current setting. With “X”
blinking, press key number 2 or 3 to scroll between “DISPLY0” disabled or not displayed and “ DISPLY1”
enabled or displayed. With the display showing the setting you wish to use, press key number 4.
Press key number 1 to return to “REFRIG”.
Press key number 2 to scroll to next routine.
*”SELBLCK1" - BLOCK SELECTION BANK 1 ROUTINE (CON 2 must be enabled - C2 1)
This function is used to set selections which will be blocked during certain periods of the day.
Press key number 4 will enter “ENABLE X”.
“ENABLEX” - Blocking Enable Routine
This function is used to disable blocking “ENABLE0” or enable blocking “ENABLE1”.
When enabled, active selections will not be allowed to vend on the days and times programmed.
Press key number 4 and the current “ENABLE” setting will be displayed.
Press key number 2 or 3 to scroll between “ENALBE0” and “ENABLE1”.
Press key number 4 with the display blinking the setting you wish to use.
Display will return to “ENABLEX”.
Press key number 2 to scroll to “STRT TIM”.
“STRT TIM” - Start Selection Blocking Routine
This function is used to set the day(s) and time to start selection blocking.
Press key number 4 and “STRT DAY” will show on the display.