Miele 07 293 000 Convection Oven User Manual


 
Once the descaling solution has been
drawn into the appliance
"Activation phase" will appear in the
display. The activation phase takes
approx. 60 minutes.
the time left for the activation phase
will be shown counting down in the
display.
The system will take in more liquid at
approximately five minute intervals. You
will hear the noise of the pump for a
moment or so.
The oven lighting and the cooling fan
will remain on during descaling.
The steam injection system will need to
be cleaned at the end of the
descaling process to remove all traces
of descaling solution.
Prompts to do this will appear in the
display.
Cleaning is carried out by flushing
approx. 1 litre of mains tap water
through the system. The water is
collected in the universal tray. This
process is repeated three times.
^
Take the universal tray out of the
oven and empty it. Place the tray
back in the oven again at the top
shelf level.
^
Unclip the plastic tube from the
container. Rinse out the container
and fill with approx. one litre of mains
tap water. Place the container in the
oven, insert the plastic tube and
secure it to the container with the
clip.
^
Start the first rinse.
^
Repeat twice.
Empty the universal tray before the
second and third rinse.
After the third rinse, residual water will
need to be evaporated from the steam
injection system.
Before proceeding, remove the
plastic tube and the container from
the oven.
The oven will heat up to "Evaporate
residual moisture". You can follow the
time in the display.
Allow the oven to cool down before
cleaning by hand. Danger of
burning.
^ Remove the universal tray and empty
it. Clean the oven interior to remove
any condensation and descaling
agent residue.
Leave the oven door open until the
oven interior is completely dry.
Cleaning and care
69