Adequate restraining means “must be attached to rear of appliance when installed.” Installation must conform to local
codes as applicable.
For units not equipped with flame safety devices, be sure all valves are turned off I)TioT to disconnecting. When recon-
necting, be sure all valves are turned off and all pilots are lit.
INSTALLATION INSTRUCTIONS FOR RESTRAINING DEVICE:
1. Restraining device bracket (item ‘IS”) and eye-bolt (item ‘7) should be positioned as closely as possible to the
appliance connector inlet and outlet connections.
2. Secure bracket (item “B”) to a wall stud. Use four each #I2 screws (item “Cl’) and plastic anchors (item “A’) if nece-
ssary.
3. Install eye-bolt (item “F”) to a frame member on the rear of the equipment. After checking carefully behind the frame
member for adequate clearance, drill a i/4” hole through the frame member.
NOTICE
l
Extreme caution
should be exercised to ensure that no appliance internal parts are damaged by
the drilling.
l
The location of the drilled hole and the eye-bolt installation should be per the appliance manufac-
turer’s recommendations.
4. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through the l/4” drilled
hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
5. Using the spring-loaded snap hooks, attach the restraining device to the bracket and the eye-bolt.
6. Using the cable clamp (item ‘ID”), adjust the restraining device extended length to prevent over-bending or kinking of
the appliance connector.
SEE ADDITIONAL INSTRUCTIONS FURNISHED WITH APPLIANCE CONNECTOR
PAGE 11