Southbend CO301HT Range User Manual


 
NOTE: Not for Scale. For Dimensional Purposes Only
WENDY’S GAS RANGE WITH CONVECTION OVEN MODEL CO-301 HT-94A
TOP VIEW
FRONT VIEW
4y
B-
FrE
r
P
B
M-
FQ--
-cI-
fS
-7
SIDE VIEW
Dimensions:
( ) = Millimeters
EXTERIOR
3/Y GAS CONN. ELECTRIC
MODEL A
B
Width Depth D
E
F
G H I J K L
M N 0
Opening Bottom
WENDY’S 36.5” 41.00” 8” 30” 29.375” 4.250”
5”
45.5” 1.875” 28.750” 6” 9.500” 36” 12.5” 4.5”
36”
15.5”
13.5”
GAS
(927) (1042) (203) (762) (746) (108) (127) (1156) (302) (730) (152) (241) (914) (315) (115) (914)
(394) (345)
,RANGE , , , . , . . . , . . , n n . n n
MODEL
OVEN INTERIOR
BURNERS (BTU each) CRATE SIZE
Width
Depth Height
Hot Top Oven
Griddle Width Depth 1 Height ~-~ckl
WENDY’S
26.125”
21.75”
14.25” 1
1 2
55”
45.5” 45”
118cu.ft.
705 Ibs.
GAS RANGE
(664)
(552)
(362)
(20,000)
(25,000) (30,000) (1397)
(1156)
(1143) 3.33 cu. m.
317 kg.
UTILITY INFORMATION:
GAS-
Total 105,000 BTU. One 3/4” flex hose male connection.
(For location, see drawing above items “L” and I‘M”).
Natural Propane
Required operating pressure: Natural Gas 4” W.C.
Propane Gas 10” W.C.
Incoming gas line and connections must not be smaller
than 314” I.D.
ELECTRIC -
STANDARD: 115/60/1 - furnished with 5 ft. cord with 3-prong
- plug. Total maximum amps 6.2.
OPTIONAL: 208/60/l or for use on 3 (190 to 219 volts) - supply
must be wired to junction box with terminal block
located at rear. Total maximum amps 4.0.
OPTIONAL: 340/60/l or for use on 3 (220 to240 volts) - supply
must be wired to junction box with terminal block
located at rear. Total maximum amps 4.0.
PAGE 3