Turbo Chef Technologies NGC-1007 Oven User Manual


 
THE CONTROL SYSTEM
16
Diagnostic Display (Screen 2)
The
DIAG key turns on or off the diagnostic display
feature. When this feature is enabled, the oven will
display temperature and cook cycle parameters when
the oven is cooking or idle.
In addition, the status indicators are displayed on the
bottom of the screen. When a status indicator is
highlighted/backlit the corresponding system is off
or open. For example:
W would indicate that the
Microwave System is off.
The
STATUS INDICATOR section below offers a more
detailed description of each indicator.
COOKS (Screen 2)
Press once to display the total number of cook counts
for all recipes. Press again to display the total amount
of time the oven has been in cook cycles.
ACCUM (Screen 2)
Press once to display the total amount of time the
magnetrons have been on. Press again to display the
total amount of time the oven has been on.
Electronic Compartment Temperature (Screen 2)
The
º
ELEC key displays the temperature inside the
electronic compartment.
F/C (Screen 2)
Changes how the oven’s temperature units are dis-
played. The
F/C key alternately selects Fahrenheit or
Celsius.
IR SI (Screen 2)
Displays the idle IR set point. This temperature is a
factory setting and should never be altered. If an
incorrect temperature has been entered, consult the
factory before changing this value.
STATUS INDICATORS
See Figures 9 and 10 on page 15.
P Primary switch – closed or open
S Secondary switch – closed or open
M Monitor switch – closed or open
t Magnetron thermostats – closed or open
h Main convection heater – off or on
i IR element – off or on
A Blower motor controller – enabled or disabled
W Microwave current – Less than or greater than 7
Amps*
* Microwave (
W) status indicator is not
highlighted/backlit when the current is more
than
7 Amps.
Status indicators are displayed at the bottom of the
display screen when the oven is in
TEST MODE, or
during normal oven operation if in
DIAGNOSTIC MODE
(DIAG was turned on). Refer to Figures 9 and 10.
If a status indicator is highlighted/backlit, the item or
component is in an un-energized or off state.
Conversely, if a status indicator is not highlighted,
the component is in an energized or on state.
PROGRAMMING
Edit Mode
The
EDIT MODE enables the operator to manually alter
recipes and the cook cavity temperature
(CCSP).
To access
EDIT MODE:
1. Simultaneously press the
UP and DOWN keys.
2. When prompted, enter the access code “9” and
then press the
ENTER key.
NOTE: If this does not provide access, refer to page 19
for enable/disable codes.
Changing the Cook Chamber Temperature
This temperature is a factory setting - exercise caution
before altering it. For best results, consult the factory
before changing this value.